Ordering Information

Nematron products are available worldwide through our network of factory-authorized distributors. For distributor contact information in your area, please visit our website at www.nematron.com and submit a Request for Quote or call Nematron’s Customer Care Center at your nearest regional sales office. EasyBuilder software can be downloaded free of charge from the Nematron website (registration required).

Part # Description
PV-6050WV1 4.3" Widescreen TFT color display, Touch, NO Ethernet (See Note 1 & 2)
PV-8056V1 5.6” TFT color display, 64K colors, Touch
PV-6070WHV1 7.0" Widescreen TFT color display, 64K colors, Touch, High Resolution, NO Ethernet (See Note 1)
PV-8070WHV1 7.0" Widescreen TFT color display, 64K colors, Touch, High Resolution
PV-6100WV1 10.0" Widescreen TFT color display, 64K colors, Touch, NO Ethernet (See Note 1)
PV-8100WV1 10.0" Widescreen TFT color display, 64K colors, Touch
PV-8104XHV1 10.4” TFT color display, 64K colors, Touch, High Resolution and Extreme Performance
PV-8121XV1 12.1” TFT color display, 64K colors, Touch, Extreme Performance
PV-8150XV1 15.0" TFT color display, 64K colors, Touch, Extreme Performance
NS-VIEWBLDR8K ViewBuilder Screen Editor Software on CD (Note: Software only - Free download at www.nematron.com)
CBL-PV8COM1 Adapter cable to break out ports for COM1-232 and COM2-232. Allows Nematron HMI cables to be connected to PV8000 units
CBL-PV8COM1-8 Adapter cable to break out ports for COM1-232 and COM2-232. Allows Nematron HMI cables to be connected to PV8000 units. NOTE: Only for use when replacing a PV-500 series unit with a PV6000/8000 series unit and a previously installed Nematron HMI Interconnect Cable is present
CBL-PV8COM3 Adapter cable to breakout COM1-485, COM3-485, and COM3-232. Allows Nematron HMI cables to be connected to PV8000 units
CBL-PV8COM3-8 Adapter cable to break out COM1-485, COM3-485, and COM3-232. Allows Nematron HMI cables to be connected to PV8000 units. NOTE: Only for use when replacing a PV-500 series unit with a PV8000 series unit and a previously installed Nematron HMI Interconnect Cable is present
COS-8056PS Screen Protectors for 5.6" units - 5 pack
COS-8080PS Screen Protectors for 8.0" units - 5 pack
COS-8104PS Screen Protectors for 10.4" units - 3 pack
COS-8121PS Screen Protectors for 12.1" units - 3 pack

Note 1: Non-Ethernet models (PV-6____) are not stocked items and may incur longer lead times than Ethernet models (PV-8____).

Note 2: This model can only connect to One RS-232 device or One RS-485 device.

Accessories - HMI Cables
Nematron HMI Cable Cross-Reference by Controller. Cables are 6-foot length unless otherwise noted. The use of either CBL-PV8COM1 or CBL-PV8COM3 adapter cable is required to connect to the PV-6000/8000 Series units (except PV-6050WV1 unit) with the cables below. Use of CBL-PV505-PLC232 to connect to the PV-6050WV1 unit is required. Direct connection with customer created cables is possible, reference the PLC connect guide in documentation included with software.

 Mfg

Model

Type/Controller Connector

PV-6000/8000 Series
(See Note 3 & 4)

A-B/Rockwell

MicroLogix 1000/1200/1500 RS-232 (DIN 8-pin) CBL-PV3-8
A-B/Rockwell MicroLogix 1500 RS-232 (DE9S) CBL-PV4-8
A-B/Rockwell SLC 5/01, 5/02, 5/03, 5/04, 5/05,
A-B Communications Interface
Module (DF1)
RS-232 (DB9) CBL-PV4-8
A-B/Rockwell SLC500 (DH485) RJ45 CBL-PV12
A-B/Rockwell A-B PLC5 (DF1) RS-232 (DB25) CBL-PV13-8
GE Series 90 RS-485 (DA15P) CBL-PV5
GE VersaMax RS-485 (DA15P) CBL-PV5
Koyo DL05/DL105/DL205/DL305/
DL350/DL405 Port 2
RS-232 (RJ12) CBL-PV10-8
Koyo DL205/DL250 CPU Port 2
(cannot be used with PV-570L)
RS-232 (15P SVGA) CBL-PV6-8
Koyo DL305/ DL340
(cannot be used with PV-570L)
RS-232 (DB25P) CBL-PV7-8
Koyo DL405 port 0 RS-232 (DA15P) CBL-PV8-8
Koyo DL405 port 1 RS-232 (DB25P) CBL-PV9-8
Koyo DL405 Port 2 RS-232 (RJ12) CBL-PV10-8
Mitsubishi A Series RS-232 (DE9P) CBL-PV2-8
Modicon Micro, Momentum RS-232 (RJ-45) CBL-PV11-8
Nematron Pointe Controller (Modbus) RS-232 (RJ12) CBL-PV10-8
Siemens Simatic TI505 RS-232 (DE9S) CBL-PV14-8
Siemens S7 Siemens S7-200 RS-485 (DB9) CBL-PV15

Note 3: When installing a PV-6000 or 8000 series unit in place of a PV-500 series with a previous version of a Nematron RS-232 HMI Interconnect Cable (not -8 suffix) the use of CBL-PV8COM1-8 or CBL-PV8COM3-8 is required.

Note 4: The use of either CBL-PV8COM1 or CBL-PV8COM3 adapter cable is required to connect these cables to the PV8000 Series units, except for the PV-6050WV1. For the PV-6050WV1 use CBL-PV505-PLC232 and do not include the "-8" suffix at the end of the controller specific cable, I.e. CBL-PV4 instead of CBL-PV4-8. Same price applies whether using "-8" in the part number or not.