Technical Specifications



 DISPLAY

M1200

M1500

M1700

M1900

Display Diagonal

12.1" (307.34mm) 15.0" (381.0mm) 17.0" (431.8mm) 19.0" (482.6mm)
Display Sizes
(Active Area H x V)
9.69" x 7.26"
(246.0mm x 184.5mm)
11.97" x 8.98"
(304.0mm x 228.1mm)
13.30" x 10.64"
(337.8mm x 270.3mm)
14.82" x 11.85"
(376.4mm x 301.0mm)
Native Resolution SVGA, 800 x 600 XGA, 1024 x 768 SXGA, 1280 x 1024 SXGA, 1280 x 1024
Displayable Colors 262K 16M 16M 16M
Brightness, Typical 400 Nit 250 Nit 300 Nit 300 Nit
Contrast Ratio, Typical 500:1 800:1 800:1 1300:1
Horizon/Vertical View
Angle, CR>5, Typical
130°/110° 150°/145° 176°/170° 178°/178°
Backlight Life, Typical 50,000 hrs 50,000 hrs 50,000 hrs 50,000 hrs

 TOUCHSCREEN (all models)

Touch Screen Technology

ELO AccuTouch, 5-wire Analog Resistive
Resolution 4096 x 4096
Positional Accuracy
(Maximum Error)
0.18" (0.19" M1900)
4.57mm (4.83mm M1900)
Positional Accuracy
(Standard Deviation of Error)
< 0.08" (< 2.0 mm)
Expected Life >35,000,000 Activations

 ELECTRICAL

AC Input Voltage

100-240 VAC, 50/60 Hz
AC Input Current M1200/1500 - 0.5 A Max
M1700 - 1.0 A Max
M1900 - 1.0 A Max
DC Input Voltage (optional) 18-36 VDC
DC Input Current (optional) M1200/1500 - 0.75 A Max
M1700 - 1.15 A Max
M1900 - 1.45 A Max
Input Power M1200/1500 - 25 W Typical
M1700 - 30 W Typical
M1900 - 35 W Typical

 ENVIRONMENTAL

Operating Non-operating

Temp.

0°C to 50°C -20°C to 60°C
Humidity 20% to 80% RH, noncondensing
Shock 15g peak acceleration, 11msec 30g peak acceleration, 11msec
Vibration
(5-2000 Hz)
0.006" peak to peak displacement, 1.0g max acceleration 0.015" peak to peak displacement, 2.5g max acceleration
Altitude * Sea level to 10,000 feet Sea level to 40,000 feet

* Altitude specification is established by using all internal component specifications.

 AGENCY

Front Panel NEMA Rating

NEMA 4/4X/12, IP65
FCC 47 CFR, Part 15, Class A
EU CE Marking Compliance CE, EN 55022: Class A,
EN 61000-3-3, EN 61000-6-2,
IEC 60950-1, RoHS compliant
Safety Agency Approvals
UL508 Listed, UL 1604 Listed *,
cUL Listed CSA C22.2, #142,
cUL Listed CSA C22.2, #143 *

* Class I Division 2, Groups A, B, C, D; Class II, Division 2, Groups F and G; Temp. Code: T4A, when installed on a flat surface of a Type 1, 4, 4X, or 12 enclosure.